Faran’s “Vigor RT” uses Online Double Conversion / High Frequency UPS technology and protects equipment against mains fluctuations, sudden voltage changes, common-mode noise, phase faults and lightning. With 2000 VA capacity, it is suitable for banks, medical centers, telecommunications, airports, IT centers, security systems, quality-control equipment and offices, providing backup power according to battery capacity and charging time. Output voltage is selectable at 208/220/230/240 V; rated input is 208/220/230/240 V, input range is 110–300 V, output frequency is 50 or 60 Hz and input frequency range is 40–70 Hz. The front-panel display shows battery capacity, load, input/output voltage and frequency, and other operating values. The time required to fully charge the batteries depends on battery capacity. Operating temperature range is 0–40°C and operating noise
is below 50 dB. Faran Vigor RT features a wide input range, Online High Frequency UPS technology, true sine-wave output with THD below 2% at linear load, advanced battery management (ABM), automatic charging with inverter off, EMI/RFI filters, advanced PFC and network-based UPS monitoring. The unit also includes a DSP processor with Cold Start and ECO Mode. Also, this UPS has no internal battery and requires 4 external battery cells.
تماس بگیرید
149 in stock
| Capacity | 2 kVA / 1800W | |||||||||
| INPUT | ||||||||||
| Input Wiring | Single-phase three-wire (1ɸ + N + PE) | |||||||||
| Rated Voltage | 208 / 220 / 230 / 240 Vac | |||||||||
| Voltage Range | 110 ~ 176 Vac (Linear derating between 50% and 100% load); 176 ~ 280 Vac (no derating); 280 ~ 300 Vac (derating 50%) |
|||||||||
| Rated Frequency | 50 / 60 Hz (auto-sensing) | |||||||||
| Frequency | 40 ~ 70 Hz | |||||||||
| Power Factor | ≥0.99 | |||||||||
| Bypass Voltage Range | – 25% ~ + 15% (settable) | |||||||||
| Total harmonic distortion (THDi) | ≤ 6% | |||||||||
| OUTPUT | ||||||||||
| Output Wiring | Single-phase (L – N) | |||||||||
| Rated Voltage | 208 / 220 /230 / 240 VAC | |||||||||
| Voltage Regulation | ±1% | |||||||||
| Frequency | 45 ~ 55 Hz or 55 ~ 65 Hz (Synchronized range); 50 / 60 ±0.1% Hz in Battery Mode | |||||||||
| Waveform | sinusoidal | |||||||||
| Power Factor | 0/9 | |||||||||
| Total Harmonic Distortion (THDv) | ≤2%(Linear Load); ≤5%(Non-Linear Load) | |||||||||
| Crest Factor | 3:1 | |||||||||
| Overload Capability | 105%~125% for 1 min, 125%~150% for 30 s, >150% for 300 ms | |||||||||
| BATTERIES | ||||||||||
| Number of battery | 48 V (S) | 48 V (H) | ||||||||
| Inbuilt Battery Standard Model | 4 * 9 Ah | / | ||||||||
| Charge Current | 1 A | 6 A | ||||||||
| Recharge Time | Standard model: 90% capacity restored in 3 hours; Long time model: depend on the capacity of battery |
|||||||||
| SYSTEM | ||||||||||
| Efficiency | ≥ 91% (Mains mode) | |||||||||
| ≥ 86% (Battery mode) | ||||||||||
| ≥ 96% (ECO mode) | ||||||||||
| Transfer Time | Mains mode to battery mode: 0ms Inverter mode to bypass mode: 4ms (typical) |
|||||||||
| Protections | Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection | |||||||||
| Communications | RS232(standard), USB / RS485 / dry contacts / SNMP (optional) | |||||||||
| Display | LCD + LED | |||||||||
| OTHERS | ||||||||||
| Operation temperature | 0°C ~ 40°C | |||||||||
| Storage temperature | -25°C ~ 55°C (without battery) | |||||||||
| Relative humidity | 0 ~ 95% (non-condensing) | |||||||||
| Altitude | ≤1000 m, derating 1% for each additional 100 m | |||||||||
| IP rating | IP 20 | |||||||||
| Noise Level at 1m | ≤ 50dB | |||||||||
| Dimensions (W × D × H)(MM) | 440*560*88 | 440*468*88 | ||||||||
| Packaged Dimensions (W × D × H)(MM) | 545*590*201 | 545*592*201 | ||||||||
| Net Weight(kg) | 18/7 | 9/7 | ||||||||
| Gross Weight(kg) | 21/8 | 13/2 | ||||||||
Reviews