Faran’s “Galaxy” uses Double Conversion (Online High Frequency UPS) technology with a transformer-based structure. It protects equipment against mains fluctuations, sudden voltage changes, common-mode noise, phase faults, lightning and similar disturbances. With a capacity of 120 kVA, this product is suitable for banks, medical equipment (MRI, CT scan), IT centers, nonlinear industrial loads and offices. Depending on battery capacity and charging time, it can supply the load after a power outage (backup). Output voltage is selectable at 380/400/415 V; rated input is 380/400/415 V and the input-voltage range is 346–456 V. The front-panel display shows battery capacity, load, input/output voltage and frequency, and other operating values. The time required to fully charge the batteries depends on battery capacity. Operating temperature is 0–40°C and operating noise is below 65 dB. Faran Galaxy features a wide input range, Online Double Conversion, true sine-wave output with THD below 2% at linear load, FULL IGBT design, advanced battery management (ABM), automatic charging with inverter off, EMI/RFI filters, advanced PFC and network-based UPS monitoring. The unit also includes a DSP processor and ECO Mode. The UPS has no internal battery and requires 48–52 external battery cells.
تماس بگیرید
149 in stock
| CAPACITY | 120kVA/ 108KW | |||||||||
| INPUT | ||||||||||
| Input wiring | Three-phase five-wire (3 + N + PE) | |||||||||
| Rated voltage | 380V / 400V / 415Vac | |||||||||
| Voltage range | 346 V ~ 456 V (full load), 304 V ~ 346 V (power derating 10%) | |||||||||
| Rated frequency | 50 / 60 Hz | |||||||||
| Frequency range | 50 / 60 Hz ± 5 Hz | |||||||||
| Power factor | ≥ 0.99 | |||||||||
| Total harmonic distortion (THDI) | ≤ 3% | |||||||||
| Input current limiting | 1.1 times of rated current ( 0.1 ~ 1.1 settable ) | |||||||||
| Rectifier delay start | 10 s ( 1 ~ 300 settable ) | |||||||||
| Bypass voltage range | ± 20% ( settable) | |||||||||
| OUTPUT | ||||||||||
| output wirig | Three-phase five-wire (3Ф + N + PE) | |||||||||
| Rated voltage | 380 V / 400 V / 415 Vac | |||||||||
| Voltage regulation accuracy | ± 1% | |||||||||
| Voltage regulation | 0 V ( ± 1 ~ 5 V settable) | |||||||||
| Frequency | synchronized with utility in mains mode ; 50 / 60 Hz ± 0.1% in battery mode | |||||||||
| Power factor | 0/9 | |||||||||
| Total harmonic distortion (THDV) | ≤ 2% ( linear load); ≤ 5% ( non – linear load) | |||||||||
| Crest factor | 3:1 | |||||||||
| Overload capability | 105% ~ 110% for 60 min , 110% ~ 125% for 10 min | |||||||||
| BATTERY | ||||||||||
| DC voltage | 600 Vdc ( support 576 Vdc / 588 Vdc / 612 Vdc / 624 Vdc ) | |||||||||
| Number of batteries | 50 pcs 12 V ( support 48 / 49 / 51 / 52 pcs ) | |||||||||
| Charging current | Charging rate ( settable) × battery capacity ( settable) × number of battery groups ( settable) | |||||||||
| SYSTEM | ||||||||||
| Efficiency | Line mode ≥ 92% ECO mode ≥ 98% |
|||||||||
| Max.number of parallel connections | 6 | |||||||||
| Protections | Short-circuit.Overload. Overtemperature. Overvoltage.Undervoltage. Battery low voltage and fan failure | |||||||||
| Communications | Standard configuration: RS232, RS485, dry contacts Optional configuration: SNMP card, temperature compensation, SMS alarms |
|||||||||
| Display | 5.7 inches LCD touch screen | |||||||||
| OTHERS | ||||||||||
| Operating temperature | 0 ~ 40°C | |||||||||
| Storage temperature | -25°C ~ 55°C ( without battery ) | |||||||||
| Humidity | 0 % ~ 95% (non-condensing) | |||||||||
| Altitude | ≤ 1000 m , Above 1000 m , derating 1% for each additional 100 m | |||||||||
| IP rating | IP 20 | |||||||||
| Noise level at 1 m | < 65 dB | |||||||||
| Dimensions ( W x D x H ) (mm) | 800 × 800 × 1800 | |||||||||
| Packaged dimensions ( W x D x H ) ( mm) | 900 x 900 x 2050 | |||||||||
| Net / Gross weight (kg) | 630 / 680 | |||||||||
Reviews
There are no reviews yet.