Faran’s “Infinity” uses Double Conversion (Online High Frequency UPS) technology and protects equipment against mains fluctuations, sudden voltage changes, common-mode noise, phase faults, lightning and similar disturbances. The system provides 20 kVA frame capacity with 5 kVA per module, making it suitable for banks, medical/laboratory equipment, data centers, IT applications and office machines. Depending on battery capacity and charging time, it can provide backup power after a mains outage. Output voltage is selectable at 240/230/220 V; rated input is 415/400/380 V and the input-voltage range is 277–478 V. The front-panel display shows battery capacity, load, input/output voltage and frequency, and other operating values. The time required to fully charge the batteries depends on battery capacity. Operating temperature is 0–40°C and operating noise is below 55 dB. Faran Infinity features a wide input range, Online Double Conversion, true sine-wave output with THD below 1% at linear load, advanced battery management (ABM), automatic charging with inverter off, EMI/RFI filters, advanced PFC and network-based UPS monitoring. The unit also includes a DSP processor with Cold Start and ECO Mode. . The UPS has no internal battery and requires 12 external battery cells.
تماس بگیرید
149 in stock
| System capacity | 20 KVA | ||||
| Input | Phase | 3Phase+Neutral+Ground, 380V/400V/415V (line to line) 220V/230V/240V (line to neutral) |
|||
| Input Voltage Range | 277~478 Vac (line-line), full load; 147~277 Vac (line-line), load decreases linearly from 100%~50% |
||||
| Rate Frequency | 50/60 HZ | ||||
| Input Frequency range | 40~70 Hz | ||||
| Input PF | >0.99 | ||||
| Input THDi | <5% (100%Linear load) | ||||
| Bypass | Rate Voltage | 220V/230V/240V, line to neutral | |||
| Rate Frequency | 50/60 Hz | ||||
| Input Voltage Range | settable, default -20% ~+15% upper limit: +25%; lower limit: -40% |
||||
| Bypass Frequency range | settable, ±1 Hz, ±3 Hz, ±5Hz | ||||
| Bypass Overload Capability |
125%, long time operation, 125%< load <130%, last for 5 minutes 130%< load < 150%, last for 1 minute, >150%, last for 200ms |
||||
| Output | Rate Voltage | 220V/230V/240V, line to neutral | |||
| Voltage Precision | ±2% | ||||
| Rate Frequency | 50/60 Hz±0.01% | ||||
| Output PF | 1 | ||||
| Output THDv | <1% linear load, <5% non-linear load (IEC/EN62040-3) | ||||
| Inverter Overload | Normal | <110% for 1 hours; 110%~130% for 10 minutes; 130%~150% for 1 minutes; >150% for 200ms |
|||
| Battery | <110% for 10 minutes; 110%~125% for 1 minute; 125%~130% for 10s; >130% for 200ms |
||||
| Synchronization Range | settable, ±0.5Hz/s~±5Hz/s, defult ±3Hz/s | ||||
| Synchronization Rate | settable, 0.5Hz/s~3Hz/s, defult 0.5Hz/s | ||||
| Output Dynamic Response | <5% (20%-80%-20% step load) | ||||
| Dynamic Recovery Time | <20ms (0%-100%-0% step load) | ||||
| Battery | Voltage | 144VDC(12pcs) | |||
| Charge Power | 0~1.8A settable(each module) | ||||
| Charge voltage Precision | 1% | ||||
| System | Efficiency | AC mode: >94.5%; ECO Mode: >98%; Battery Mode: >90% | |||
| Display | LCD+LED, 7ʺ touch color screen and keyboard | ||||
| IP Class | IP20 | ||||
| Interface | Standard: RS232, RS485, USB, Dry contacts | ||||
| Option | SNMP card, AS400 card, parallel kits, SPD, dust filter, LBS | ||||
| Temperature | Operation: 0-40 ˚C Storage: -40~70 ˚C | ||||
| Relative Humidity | 0-95% Non-condensing | ||||
| Altitude | <1000m, Load derated 1% per 100m From 1000~2000m | ||||
| Noise (dB) | 55 dB @ 100% load | ||||
| Applicable Standard | Safety: IEC/EN 62040-1 EMC:IEC/EN 62040-2 PERFORMANCE: IEC/EN 62040-3 | ||||
| Physical | power | Battery | |||
| Weight(kg) | Cabinet: | 66.5kg | 67.3kg | ||
| Module: | 7.5kg | 17.8kg | |||
| Dimention(W*D*H)(mm) | Cabinet: | 443*695*928 | |||
| Module: | 200*431*84.5 | 200*516*84.5 | |||