Faran’s “Galaxy S” uses Double Conversion (Online High Frequency UPS) technology with a transformer-based design, protecting equipment against mains fluctuations, sudden voltage changes, common-mode noise, phase faults, lightning and similar disturbances. With a capacity of 30 kVA, this product is suitable for banks, medical equipment (MRI, CT scan), IT centers, nonlinear industrial loads, offices and quality-control equipment. Depending on battery capacity and charging time, it can supply the load after a power outage (backup). Output voltage is selectable at 380/400/415 V; rated input is 380/400/415 V and the input-voltage range is ±25% of nominal. The front-panel display shows battery capacity, load, input/output voltage and frequency, and other operating values. The time required to fully charge the batteries depends on battery capacity. Operating temperature is 0–40°C and operating noise is below 55 dB. Faran Galaxy features a wide input-voltage range, Online Double Conversion, true sine-wave output, advanced battery management (ABM), automatic charging with the inverter off, a thyristor rectifier, EMI/RFI input/output filters, advanced PFC and network-based UPS monitoring. The unit also includes a DSP processor with Cold Start and ECO Mode. The UPS has no internal battery and requires 28–32 external battery cells.
تماس بگیرید
149 in stock
| Capacity | 30 kVA | ||||||||
| INPUT | |||||||||
| Rated Voltage | 380 V / 400 V / 415 Vac | ||||||||
| Voltage range | ± 25 % | ||||||||
| Rated frequency | 50 / 60 Hz | ||||||||
| Frequency range | 50 / 60 Hz ± 5 Hz | ||||||||
| Power factor | ≥0.95 (with filter) | ||||||||
| Bypass voltage range | ± 20 % (settable) | ||||||||
| Delayed start of rectifier | 1 ~ 300 s (settable via display panel) | ||||||||
| ECO voltage range | ± 10 % (settable) | ||||||||
| OUTPUT | |||||||||
| Voltage | 380 V / 400 V / 415 Vac | ||||||||
| Voltage regulation | ± 1 % | ||||||||
| Frequency | Synchronized with utility in main mode ; 50/60Hz ±0.1% in battery mode | ||||||||
| Waveform | Synusoidal | ||||||||
| Power factor | 0/9 | ||||||||
| Crest factor | 3:1 | ||||||||
| Transfer time | AC mode to battery mode : 0ms | ||||||||
| Inverter mode to bypass mode : 0ms | |||||||||
| Inverter mode to ECO mode : 0 ~ 4ms | |||||||||
| Overload | 105% :long time running | ||||||||
| 110% ~ 125% for 10min | |||||||||
| 125% ~ 200% for 200ms | |||||||||
| >200% for 100ms | |||||||||
| Slight adjustment of inverter output voltage | ±5V | ||||||||
| BATTERIES | |||||||||
| DC voltage | 12V * configured battery number (settable via display panel) | ||||||||
| Number of battery | 28 ~ 32 pcs (settable) | ||||||||
| Charging current | 10A default /settable | ||||||||
| Charging | Three-stage charging, auto switch floating / equalizing charge | ||||||||
| Battery state display | Display battery backup time , battery remaining capacity | ||||||||
| Battery selt-test | Settable periodic self-test; manually configurable test time and voltage | ||||||||
| SYSTEM | |||||||||
| Efficiency | In line mode: Max 93% ; ECO mode: ≥98% | ||||||||
| Max. Parallel numbers | 6 | ||||||||
| Protections | Short-circuit-overload-overvoltage-undervoltage-low battery-overtemperature-fan fault | ||||||||
| Communication | RS232/RS485/dry contacts (standard) , SNMP (optional) | ||||||||
| IP rating | IP20 | ||||||||
| EMI | EN62040-2 | ||||||||
| EMS | IEC61000-4-2 (ESD) | ||||||||
| IEC61000-4-3 (RS) | |||||||||
| IEC61000-4-4 (EFT) | |||||||||
| IEC61000-4-5 (surge) | |||||||||
| OTHERS | |||||||||
| Humidity | 0~95% RH@0~40˚C(non-condensing) | ||||||||
| Noise level | 55 dB | ||||||||
| Dimensions (W * D *H) (mm) | 400 * 800 * 1100 | ||||||||
| Packaged dimensions (W * D * H) (mm) | 490*920*1250 | ||||||||
| Net / Gross weight (kg) | 210/252 | ||||||||