{"id":11294,"date":"2025-06-29T11:39:08","date_gmt":"2025-06-29T08:09:08","guid":{"rendered":"https:\/\/fao-co.com\/product\/asenware-aw-cfp2166-8-8-zone-conventional-control-panel\/"},"modified":"2025-06-29T11:39:08","modified_gmt":"2025-06-29T08:09:08","slug":"asenware-aw-cfp2166-8-8-zone-conventional-control-panel","status":"publish","type":"product","link":"https:\/\/fao-co.com\/en\/product\/asenware-aw-cfp2166-8-8-zone-conventional-control-panel\/","title":{"rendered":"Asenware AW-CFP2166-8 8-Zone Conventional Control Panel"},"content":{"rendered":"<div class=\"d-flex justify-content-between align-items-center\">\n<h6>8-zone conventional control panel<\/h6>\n<\/div>\n<div class=\"short-desc mt-30\">\n<ul>\n<li dir=\"rtl\">Modular expansion up to 32 zones<\/li>\n<li dir=\"rtl\">Two access levels controlled by key lock<\/li>\n<li dir=\"rtl\">5 V and 24 V DC outputs<\/li>\n<li dir=\"rtl\">FIRE and FAULT output signals<\/li>\n<li dir=\"rtl\">2 general alarm sounder outputs<\/li>\n<li dir=\"rtl\">Each zone can be disabled with one button<\/li>\n<li dir=\"rtl\">Includes RESET for panel restart, SILENCE for muting buzzer\/sounders, and EVACUATE for manually activating the general evacuation alarm<\/li>\n<li dir=\"rtl\">Battery protection when charge drops below 21 V while panel power is connected<\/li>\n<li dir=\"rtl\">Optional GSM module for sending fire-alarm SMS messages<\/li>\n<\/ul>\n<\/div>\n<table class=\"table product-spec-table table-bordered table-striped\" dir=\"ltr\">\n<tbody>\n<tr>\n<th>Brand<\/th>\n<td>Asenware<\/td>\n<\/tr>\n<tr>\n<th>AC INPUT<\/th>\n<td>220VAC 50HZ<\/td>\n<\/tr>\n<tr>\n<th>DC OUTPUT<\/th>\n<td>24VDC typical<\/td>\n<\/tr>\n<tr>\n<th>Voltage for MCU<\/th>\n<td>5V for power board MCU, 3.3V for others<\/td>\n<\/tr>\n<tr>\n<th>Current at 24VDC from PSE<\/th>\n<td>450mA standby current<\/td>\n<\/tr>\n<tr>\n<th>Maximum current from PSE<\/th>\n<td>2A except batteries charge<\/td>\n<\/tr>\n<tr>\n<th>Batteries current<\/th>\n<td>1.85A maximum, current limited<\/td>\n<\/tr>\n<tr>\n<th>Auxiliary output<\/th>\n<td>24VDC +\/- 10%, 100 mA max, current limited, monitored<\/td>\n<\/tr>\n<tr>\n<th>Batteries<\/th>\n<td>2*12V\/ 2.3Ah sealed lead acid gel, self-regulated 2*12V\/ 7Ah if needed<\/td>\n<\/tr>\n<tr>\n<th>Battery replace Resistance<\/th>\n<td>2\u03a9\u00b110% if needed<\/td>\n<\/tr>\n<tr>\n<th>Battery low-voltage protection<\/th>\n<td>21V<\/td>\n<\/tr>\n<tr>\n<th>Detectors connection allowed each zone<\/th>\n<td>20 (except MCPs)<\/td>\n<\/tr>\n<tr>\n<th>Zone alarm current<\/th>\n<td>6mA minimum\/ 27mA maximum<\/td>\n<\/tr>\n<tr>\n<th>Sounder output<\/th>\n<td>2*0.75A maximum<\/td>\n<\/tr>\n<tr>\n<th>Fire protection<\/th>\n<td>100mA maximum<\/td>\n<\/tr>\n<tr>\n<th>Fire routing<\/th>\n<td>100mA maximum<\/td>\n<\/tr>\n<tr>\n<th>Fault routing<\/th>\n<td>100mA maximum<\/td>\n<\/tr>\n<tr>\n<th>Communication protocol<\/th>\n<td>2 wires RS485 bus system<\/td>\n<\/tr>\n<tr>\n<th>Relay contacts rating<\/th>\n<td>Dry contacts (NO\/NC) 1A @24VDC<\/td>\n<\/tr>\n<tr>\n<th>EOL resistor for zone<\/th>\n<td>6.8K 1W<\/td>\n<\/tr>\n<tr>\n<th>EOL resistor for outputs<\/th>\n<td>6.8K 1W<\/td>\n<\/tr>\n<tr>\n<th>Fuse on power board<\/th>\n<td>3A\/ 250V glass tube fuse 20mm<\/td>\n<\/tr>\n<tr>\n<th>Fuse on EMI board<\/th>\n<td>1A\/ 250V glass tube fuse 20mm<\/td>\n<\/tr>\n<tr>\n<th>Environmental<\/th>\n<td>Class A temperature range: -5 to 50\u00b0C Humidity: 5 to 95% RH, non-condensing<\/td>\n<\/tr>\n<tr>\n<th>Terminal blocks rating<\/th>\n<td>All terminals rated for 12 to18 AWG (0.75 to 2.5 mm2)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<div class=\"short-desc mt-30\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<div class=\"d-flex justify-content-between align-items-center\">\n<h6>8-zone conventional control panel<\/h6>\n<\/div>\n<div class=\"short-desc mt-30\">\n<ul>\n<li dir=\"rtl\">Modular expansion up to 32 zones<\/li>\n<li dir=\"rtl\">Two access levels controlled by key lock<\/li>\n<li dir=\"rtl\">5 V and 24 V DC outputs<\/li>\n<li dir=\"rtl\">FIRE and FAULT output signals<\/li>\n<li dir=\"rtl\">2 general alarm sounder outputs<\/li>\n<li dir=\"rtl\">Each zone can be disabled with one button<\/li>\n<li dir=\"rtl\">Includes RESET for panel restart, SILENCE for muting buzzer\/sounders, and EVACUATE for manually activating the general evacuation alarm<\/li>\n<li dir=\"rtl\">Battery protection when charge drops below 21 V while panel power is connected<\/li>\n<li dir=\"rtl\">Optional GSM module for sending fire-alarm SMS messages<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"featured_media":11295,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[188,185],"product_tag":[],"class_list":{"0":"post-11294","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-asenware","7":"product_cat-fire-alarm-suppression","9":"first","10":"instock","11":"taxable","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/fao-co.com\/en\/wp-json\/wp\/v2\/product\/11294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fao-co.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/fao-co.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/fao-co.com\/en\/wp-json\/wp\/v2\/comments?post=11294"}],"version-history":[{"count":0,"href":"https:\/\/fao-co.com\/en\/wp-json\/wp\/v2\/product\/11294\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fao-co.com\/en\/wp-json\/wp\/v2\/media\/11295"}],"wp:attachment":[{"href":"https:\/\/fao-co.com\/en\/wp-json\/wp\/v2\/media?parent=11294"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/fao-co.com\/en\/wp-json\/wp\/v2\/product_brand?post=11294"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/fao-co.com\/en\/wp-json\/wp\/v2\/product_cat?post=11294"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/fao-co.com\/en\/wp-json\/wp\/v2\/product_tag?post=11294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}