Faran’s “Trust” uses Line-Interactive technology with Cold Start and protects equipment against mains fluctuations, sudden voltage changes, lightning and similar disturbances. With 2000 VA capacity, this product is suitable for appropriate home, commercial and office applications. Output voltage is selectable at 200/220/230/240 V; rated input is 200/220/230/240 V, input range is 165–280 V, and the unit supports 50/60 Hz input frequency within its specified tolerance. The front-panel display shows battery capacity, load, input/output voltage and frequency, and other operating values. Full battery charging takes about 8 hours. Operating temperature is 0–40°C and operating noise is below 50 dB. Faran Trust features a wide input-voltage range, Line-Interactive technology, true sine-wave output, advanced battery management and network-based UPS monitoring.
تماس بگیرید
149 in stock
| CAPACITY | 2kVA / 1.6kW | ||||
| DC INPUT | |||||
| Rated voltage | 36 V (S), 48 V (H) | ||||
| DC input range (default) | 30 ~ 45 V(S), 40 ~ 60 V(H) | ||||
| AC INPUT | |||||
| AC input range (bypass mode) | 0 ~ 242 V / 264 V / 267 V /288 Vac for 200 V / 220 V /230 V / 240 VAC ± 10 Vac | ||||
| AC input range (mains mode) | 200 V: 145 ~ 260 Vac 220 V: 165 ~ 280 Vac 230 V: 175 ~ 290 Vac 240 V: 185 ~ 300 Vac | ||||
| Ferquency input range | 50 Hz / 60 Hz(auto-sense), 50Hz / 60 Hz ± 5% ~ 15% | ||||
| Generator connection | Available (generator input power is settable) | ||||
| OUTPUT | |||||
| Inverter output range | 200 V / 220 V / 230 V / 240 Vac ± 5%(settable) | ||||
| AC output range(bypass mode) | 0 ~ 242 V / 264 V / 276 V / 288 Vac for 200 V / 220 V / 230 V / 240 Vac ± 10Vac | ||||
| AC output range(mains mode) | 200 V: 166 ~ 226 Vac 220 V: 188 ~ 245 Vac 230V:199~254Vac 240 V: 210 ~ 264 Vac | ||||
| Output frequency | 50 / 60 Hz ± 0.3 Hz (settable) | ||||
| Waveform | Pure sine wave | ||||
| inverter efficiency | Max,85% | ||||
| Energy saving mode | settable (<3% load), enter in 80 s | ||||
| No-load shutdown | settable (<3% load), shutdown in 80 s | ||||
| Transfer time | ≤ 10 ms | ||||
| THDV(resistive load) | ≤ 5 % | ||||
| Protections | Overload, short circuit (inverter), battery low voltage, battery overcharge, overtemperature | ||||
| Overload time (mains mode) | 120 s for 110%, 80 s for 125%, 10 s for 150% (transfer to bypass mode) | ||||
| Overload time (inverter mode) | 80 s for 110%, 10 s for 125%, 5 s for 150% (shutdown directly) | ||||
| Mute | Automatic mute in 60 s or by manual | ||||
| BATTERY | |||||
| Battery capacity(H: external expansion) | 12V/9Ah×3 (H: 12V×4) | ||||
| Charging current | Standard model(S): 1A (default) | ||||
| Long time model(H): 10A (default);< 10A, set step 1 A; ≥ 10A, set step 5 A | |||||
| Max. 20 A (H) | |||||
| Equalizing charge voltage | Single battery 14.1 Vdc (default), 13.6 ~ 15 Vdc adjustable | ||||
| Floating charge voltage | Single battery 13.5 Vdc (default), 13.2 ~ 14.6 Vdc adjustable | ||||
| low voltage alarm point | Single battery 10.8 Vdc (default), 9.6 ~ 13 Vdc adjustable | ||||
| low voltage shutdown point | Single battery 10.2 Vdc (default), 9.6 ~ 11.5 Vdc adjustable | ||||
| COMMUNICATIONS | |||||
| USB+RJ45 | Supports Windows®98 / 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10 | ||||
| SNMP (optional) | Power management from SNMP manager and web browser (standard with slot) | ||||
| OTHERS | |||||
| Operating temperature | 5°C ~ 40°C | ||||
| Operating humidity | Relative humidity ≤ 93% | ||||
| Noise level | ≤ 50 dB(1M) | ||||
| Tower | Dimensions(W × D × H) (mm) | 144×410×215(S) 144×345×215(H) |
|||
| Packaged dimensions(W × D × H) (mm) | 236*492*316 (S) 236×427×316(H) |
||||
| Net weight(kg) | 18.5(S) 17.8(H) | ||||
| Gross weight(kg) | 19.8(S) 18.8(H) | ||||
| Rack mount | Dimensions(W × D × H) (mm) | 440 × 410 × 132 (S) | |||
| Packaged dimensions(W × D × H) (mm) | 611 × 505 × 235 (S) | ||||
| Net weight(kg) | 21.3(S) | ||||
| Gross weight(kg) | 24.5(S) | ||||
| S=Standard Model H=Long Time Model> |
|||||