Faran’s “Galaxy S” uses Double Conversion (Online High Frequency UPS) technology with a transformer-based design, protecting equipment against mains fluctuations, sudden voltage changes, common-mode noise, phase faults, lightning and similar disturbances. With a capacity of 10 kVA, this product is suitable for banks, medical equipment (MRI, CT scan), IT centers, nonlinear industrial loads, offices and quality-control equipment. Depending on battery capacity and charging time, it can supply the load after a power outage (backup). Output voltage is selectable at 380/400/415 V; rated input is 380/400/415 V and the input-voltage range is ±25% of nominal. The front-panel display shows battery capacity, load, input/output voltage and frequency, and other operating values. The time required to fully charge the batteries depends on battery capacity. Operating temperature is 0–40°C and operating noise is below 65 dB. Faran Galaxy features a wide input-voltage range, Online Double Conversion, true sine-wave output, advanced battery management (ABM), automatic charging with the inverter off, a thyristor rectifier, EMI/RFI input/output filters, advanced PFC and network-based UPS monitoring. The unit also includes a DSP processor with Cold Start and ECO Mode. . The UPS has no internal battery and requires 28–32 external battery cells.
تماس بگیرید
149 in stock
| Rated capacity | 200 kVA/200 kW | ||||
| Number of power modules | 4 | ||||
| Rated capacity of power module | 50 kVA | ||||
| INPUT | |||||
| Input wiring | 3 PH + N + PE | ||||
| Rated voltage | 380 / 400 / 415 Vac | ||||
| Voltage range | 138 ~ 485 Vac (305 ~ 485 Vac without power downgrading; 138 ~ 305 Vac with linear downgrading 40%) |
||||
| Input frequency | 40 ~ 70 Hz | ||||
| Power factor | ≥ 0.99 | ||||
| Current distortion | ˂ 3% | ||||
| BATTERIES | |||||
| Battery voltage | ±240 Vdc (±180 ,±192 ,±204 , ±216 , ±228 , ±252 , ±264 , ±276 selectable) | ||||
| Number of battery | 40 pcs 12 V batteries (30/32/34/36/38/42/44/46 pcs selectable) | ||||
| OUTPUT | |||||
| Output wiring | 3 PH + N + PE | ||||
| Rated voltage | 380 / 400 / 415 / Vac ±1% | ||||
| Frequency | Synchronized with utility in mains power mode ; 50 Hz / 60 Hz ± 0.25% in battery mode |
||||
| Power factor | 1 | ||||
| Voltage distortion | ≤ 1% with linear load / ≤ 3% with non-linear load | ||||
| Crest factor | 3:1 | ||||
| Inverter overload capacity | 105 % < load ≤ 110% : transfer to bypass in 60 min 110 % < load ≤ 125% : transfer to bypass in 10 min 125 % < load ≤ 150% : transfer to bypass in 1 min load > 150% : transfer to bypass in 200 ms |
||||
| Bypass overload capacity | Load ≤ 135% for long term ; < 1000 % load for 100 ms | ||||
| SYSTEM | |||||
| Efficiency | 96/50% | ||||
| Max. number of parallel connection | 4 Units | ||||
| Transfer time | 0 ms | ||||
| Protections | Short circuit protection , overload protection , over temperature protection , battery low voltage protection , output over/low voltage protection , fans failure protection etc |
||||
| Communications | RS485 , dry contacts , SNMP | ||||
| Display | 7 inches LCD touch screen | ||||
| OTHERS | |||||
| Operation temperature | 0 ~ 40˚C | ||||
| Storage temperature | -40˚C ~ +70˚C | ||||
| Humidity | 0 ~ 95% (non-condensing) | ||||
| Altitude | ≤1000 m. Above, derating 1% for each additional 100m | ||||
| Protection level | IP20 | ||||
| Noise level at 1m | < 65 dB | ||||
| Cabinet demensions (W*D*H){mm) | 600 * 850 * 2000 | ||||
| UPS module demensions (W*D*H){mm) | 440 * 620 * 130 | ||||
| Cabinet weight (kg) | 233 | ||||
| Power module weight (kg) | 32 | ||||
Reviews
There are no reviews yet.